Mechanical
Data |
Housing: |
Copper-Zinc Alloy, Die Casting & Aluminum |
Housing
Surface:
|
Nickel Plated Brass, Other Surfaces Upon Request |
Inserts
(For Contacts):
|
Thermoplastic Polyamide PA 6 (Nylon 6/6), PBT
Fire protection class V-0 |
Contacts: |
Brass
Alloy |
Contact
Surface at point of Contact:
|
Nickel and gold plated (0,25µm Au) |
Minimum
Mating Cycles: |
> 1000 |
Seals
/ O-Rings: |
Buna-N standard, optional FPM |
Temperature
Range:
|
-40°F to 257°F (-40°C to 125°C) |
Type
of Contacts:
|
Crimp, solder, dip solder (PCB) |
Protection: |
IP
67 / IP 69 K per EN 60529 (connected), NEMA 4x |
Cable
Diameter Range: |
.12 - .67" (3 - 14 mm) |
|
|
Electrical
Data |
Number of Positions |
6 |
7 |
9 (8+1) |
12 |
16 |
17 |
19 (16
+ 3) |
Number of Contacts |
6 |
7 |
|
12 |
16 |
17 |
|
Contact Ø (mm) |
2 |
2 |
|
1 |
1 |
1 |
|
Nominal Current [A] |
20 |
20 |
|
8 |
8 |
8 |
|
Nominal Voltage [V~]
Degree of Protection 2* |
630 |
630 |
500 |
500 |
400 |
400 |
320 |
Nominal Voltage [V~]
Degree of Protection 3* |
300 |
300 |
200 |
200 |
160 |
160 |
100 |
Test Voltage (Breakdown Voltage) [V~] |
2500 |
2500 |
2500 |
2500 |
1500 |
1500 |
1500 |
Insulation Resistance [MΩ] |
>1010 |
>1010 |
>1010 |
>1010 |
>106 |
>106 |
>106 |
Max. Contact Resistance [mΩ] |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
|
|
Number of Poles |
Coding Possibilities |
Coding |
6-pole 7-pole
9-pole
12-pole
16-pole
17-pole
19-pole
|
N, S, H, X, Y and Z N, S, H, X and Y N, S, H, X and Y N, S, H, X, Y and Z N, S, H, X, Y and Z N, S, H, X, Y and Z N, S, H, X and Y |
|
As standard coding groove N is opened To use other codings please remove the coding borrier. |
|
|
*Degree of Protection
Potential dirt accumulation of a disconnected connector in a certain environment. |
*Degree of Protection 2
No permanent conductive dirt accumulation will occur. Temporary conductive dirt accumulation, such as condensation, is possible. Typical for households, offices, laboratories and test labs. |
*Degree of Protection 3
Conductive, as well as dry non-conductive dirt accumulation can occur. It can be temporarily conductive due to condensation. Typical for industrial and factory environments. |
|
|
|