Mechanical
Data |
Housing: |
Copper-Zinc
Alloy, Die Casting & Aluminum |
Housing
Surface:
|
Nickel Plated Brass, Other Surfaces Upon Request |
Inserts
(For Contacts):
|
Thermoplastic Polyamide PA 6 (Nylon 6/6), PBT
Fire protection class V-0 |
Contacts: |
Brass
Alloy |
Contact
Surface at point of Contact:
|
Nickel and gold plated (0,25µm Au) |
Minimum Mating Cycles: |
> 1000 |
Seals
/ O-Rings: |
Buna-N standard, optional Viton® (Viton® is a registered trademark of DuPont) |
Temperature
Range: |
-40°F to 257°F
(-40°C to 125°C) |
Type
of Contacts: |
Crimp |
Protection: |
IP
67 / IP 69 K per EN 60529 (connected), NEMA 4x |
Cable
Diameter Range: |
.28 - .67" (7 - 17 mm) |
|
|
Electrical
Data |
Number
of Positions |
5 +
PE |
4 +
3 + PE |
Number of Contacts |
6 |
|
Contact Ø (mm) |
2 |
|
Nominal Current [A] |
28 |
|
Nominal Current [V~] |
800 |
|
Test Voltage (Breakdown
Voltage) [V~] |
600 |
|
Test Voltage (Breakdown
Voltage)[V~] |
4000 |
|
Insulation Resistance
[MΩ] |
> 1013 |
> 1013 |
Max. Contact Resistance
[mΩ] |
3 |
3 |
|
|
*Degree of Protection
Potential dirt accumulation of a disconnected connector in a certain environment. |
*Degree of Protection 2
No permanent conductive dirt accumulation will occur. Temporary conductive dirt accumulation, such as condensation, is possible. Typical for households, offices, laboratories and test labs. |
*Degree of Protection 3
Conductive, as well as dry non-conductive dirt accumulation can occur. It can be temporarily conductive due to condensation. Typical for industrial and factory environments. |
|
|
|